ORION 2 VISUAL FLOW
Electro-magnetic flow meter
1" NPT Male Threads
Includes Power Cable
Advantages
• No mechanical moving parts inside the pipe
• Performances independent from fluid density and viscosity
• Low sensitivity to turbulence
• High precision
• Low maintenance
Features
• Instant flow display
• Total delivered (or filled) quantity display
• Set-up quantity to be filled
• Re-set total delivered quantity
• Unit of measure: litres or US Gallons
• Typical error: 0,5% - full scale ±1 digit
• Working pressure: up to 40 bar
• Power supply: 11 to 15 Vdc
• 0-12 Vdc pulse output with frequency proportional to rate
• Max consumption: 300 mA
• Output only by flowing fluid
• Available c/w threaded fittings in fyber glass reinforced Nylon (20 bar) or brass (40 bar)
• Parts in contact with fluid made of polypropylene and Stainless Steel 316
Code |
46212A41414 |
F Itting |
G 1 |
Flow rate |
10÷200 l/min |
Flow rate |
2.6÷53 US GPM |
MAX Pressure |
20 bar |
MAX Pressure |
290 PSI |
Pressure Drop |
0.5 bar |
Pressure Drop |
7 PSI |
Internal Passage |
18,5 mm |
Impulsi |
300 pls/l |
Impulsi |
1135 pls/Gal |